| Assessment Year | 2010 |
|---|---|
| Principal Product | Farming Equipment |
| NAICS | 332216: Saw Blade and Handtool Manufacturing |
| SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
132,507
ft2
|
| Annual Production | 15,000,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $118,585 | 3,231,600 |
kWh
|
$0.037 |
| Electricity Demand | $13,100 | 14,556 |
kW-mo/yr
|
$0.90 |
| Electricity Fees | $186,375 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,404 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,396 | $19,479 |
$18,725
213,595
kWh
|
$384
-
kW-mo/yr
|
$287 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,710 | $398 |
$3,654
41,326
kWh
|
- | $56 | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,482 | $274,410 |
$3,085
35,195
kWh
|
$346
-
kW-mo/yr
|
$51 | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $1,420 | $13,240 |
$1,349
15,386
kWh
|
$50
-
kW-mo/yr
|
$21 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,363 | $6,334 |
$1,218
13,890
kWh
|
$125
-
kW-mo/yr
|
$20 | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $682 | $945 |
$647
7,384
kWh
|
$24
-
kW-mo/yr
|
$11 | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $351 | $1,687 |
$332
3,788
kWh
|
$14
-
kW-mo/yr
|
$5 | |
| TOTAL RECOMMENDED | $30,404 | $316,493 |
$29,010
330,564
kWh
|
$943
-
kW-mo/yr
|
$451 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs