Assessment Year | 2010 |
---|---|
Principal Product | PLASTICS |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $10 M to 50M |
# of Employees | 33 |
Plant Area |
38,000
ft2
|
Annual Production | 6,000
ton
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $320,001 | 3,296,480 |
kWh
|
$0.097 |
Electricity Demand | $21,018 | 5,764 |
kW-mo/yr
|
$3.65 |
Electricity Fees | $5,156 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,216 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,040 | $6,573 |
$8,822
210,053
kWh
|
$1,069
-
kW-mo/yr
|
$149 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,328 | $356 |
$2,295
54,636
kWh
|
- | $33 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $524 | $1,365 |
$447
10,644
kWh
|
$69
-
kW-mo/yr
|
$8 | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $324 | $490 |
$265
6,305
kWh
|
$55
-
kW-mo/yr
|
$4 | |
TOTAL RECOMMENDED | $13,216 | $8,784 |
$11,829
281,638
kWh
|
$1,193
-
kW-mo/yr
|
$194 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs