Assessment Year | 2007 |
---|---|
Principal Product | Radiators |
NAICS | 332313: Plate Work Manufacturing |
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
138,000
ft2
|
Annual Production | 325,000
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $278,226 | 6,150,000 |
kWh
|
$0.045 |
Electricity Demand | $39,029 | 12,789 |
kW-mo/yr
|
$3.05 |
Electricity Fees | $24,873 | - |
|
- |
Natural Gas | $250,741 | 24,873 |
MMBtu
|
$10.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,643 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,342 | $27,930 |
$18,349
448,243
kWh
|
$2,548
-
kW-mo/yr
|
$1,445 | - | - | |
02 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $20,700 | $6,500 | - | - | - | - | $20,700 | |
03 | 2.2515: Use optimum thickness insulation | $7,075 | $2,156 | - | - | - |
$7,075
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,010 | $11,969 |
$2,474
60,431
kWh
|
$342
-
kW-mo/yr
|
$194 | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,195 | $231 |
$1,045
47,669
kWh
|
- | $150 | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,321 | $5,175 |
$1,045
25,563
kWh
|
$194
-
kW-mo/yr
|
$82 | - | - | |
TOTAL RECOMMENDED | $55,643 | $53,961 |
$22,913
581,906
kWh
|
$3,084
-
kW-mo/yr
|
$1,871 |
$7,075
-
MMBtu
|
$20,700 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs