| Assessment Year | 2007 |
|---|---|
| Principal Product | Venetian Blind Components |
| NAICS | 337920: Blind and Shade Manufacturing |
| SIC | 2591: Drapery Hardware and Window Blinds and Shades |
| Sales Range | $10 M to 50M |
| # of Employees | 163 |
| Plant Area |
300,000
ft2
|
| Annual Production | 240,000
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $303,195 | 4,487,312 |
kWh
|
$0.068 |
| Electricity Demand | $106,572 | 9,689 |
kW-mo/yr
|
$11.00 |
| Electricity Fees | $1,458 | - |
|
- |
| Natural Gas | $328,659 | 26,351 |
MMBtu
|
$12.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $42,409 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,470 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,634 | $62,998 |
$18,924
441,112
kWh
|
$10,710
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,986 | $23,207 |
$2,801
65,302
kWh
|
$2,185
-
kW-mo/yr
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,166 | $176 |
$2,166
50,474
kWh
|
- | - | |
| 04 | 2.6214: Shut off pilots in standby equipment | $1,669 | $185 | - | - |
$1,669
-
MMBtu
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,304 | $2,700 |
$1,318
30,713
kWh
|
$986
-
kW-mo/yr
|
- | |
| 06 | 3.6124: Burn waste oil for heat | $1,265 | $2,186 | - | - |
$1,265
-
MMBtu
|
|
| 07 | 2.2437: Recover waste heat from equipment | $385 | $476 | - | - |
$385
-
MMBtu
|
|
| TOTAL RECOMMENDED | $42,409 | $91,928 |
$25,209
587,601
kWh
|
$13,881
-
kW-mo/yr
|
$3,319
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,470 | $2,876 |
$3,484
81,187
kWh
|
$986
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs