Assessment Year 2006
Principal Product Laboratory Furniture
NAICS 337127: Institutional Furniture Manufacturing
SIC 2531: Public Building and Related Furniture
Sales Range $10
M
to 50
M
# of Employees 115
Plant Area 86,000
ft2
Annual Production 18,000
pieces
Production Hrs. Annual 2,695
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $107,313 1,304,800
kWh
Electricity Demand $17,726 5,353
kW-mo/yr
Electricity Fees $15,044 -
Natural Gas $47,316 3,234
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $53,969 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,236

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.3412: Use waste heat to produce steam to drive a steam turbine-generator $48,733 $70,000 $14,958
169,785
kWh
$2,435
-
kW-mo/yr
$31,340
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,385 $16,886 $2,950
33,484
kWh
$432
-
kW-mo/yr
$3
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,851 $244 $1,850
20,993
kWh
- $1
TOTAL RECOMMENDED $53,969 $87,130 $19,758
224,262
kWh
$2,867
-
kW-mo/yr
$31,344
TOTAL IMPLEMENTED $5,236 $17,130 $4,800
54,477
kWh
$432
-
kW-mo/yr
$4
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs