Assessment Year | 2006 |
---|---|
Principal Product | Burial Caskets |
NAICS | 339995: Burial Casket Manufacturing |
SIC | 3995: Burial Caskets |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
650,000
ft2
|
Annual Production | 155,000
pieces
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $466,838 | 11,392,920 |
kWh
|
$0.041 |
Electricity Demand | $72,863 | 20,966 |
kW-mo/yr
|
$3.48 |
Electricity Fees | $425,483 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $61,791 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,825 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $45,413 | $160,000 |
$30,849
573,255
kWh
|
$6,552
-
kW-mo/yr
|
$8,012 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,548 | $26,994 |
$9,366
174,043
kWh
|
$1,792
-
kW-mo/yr
|
$2,390 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,825 | $225 |
$1,502
27,918
kWh
|
- | $323 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,005 | $7,451 |
$488
11,152
kWh
|
$228
-
kW-mo/yr
|
$289 | |
TOTAL RECOMMENDED | $61,791 | $194,670 |
$42,205
786,368
kWh
|
$8,572
-
kW-mo/yr
|
$11,014 | ||
TOTAL IMPLEMENTED | $1,825 | $225 |
$1,502
27,918
kWh
|
- | $323 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs