ITAC Assessment: MS0286
ITAC logo
ITAC Assessment: MS0286
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Metal Building
NAICS 332311: Prefabricated Metal Building and Component Manufacturing
SIC 3448: Prefabricated Metal Buildings and Components
Sales Range $50
M
to 100
M
# of Employees 294
Plant Area 306,800
ft2
Annual Production 40,000
ton
Production Hrs. Annual 6,120
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $194,926 5,454,000
kWh
Electricity Demand $145,158 14,273
kW-mo/yr
Electricity Fees $(-42,544.0) -
Natural Gas $147,056 12,482
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,625 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7229: Air condition only space necessary $6,625 - $1,575
44,064
kWh
$6,035
-
kW-mo/yr
$(-985.0)
TOTAL RECOMMENDED $6,625 - $1,575
44,064
kWh
$6,035
-
kW-mo/yr
$(-985.0)
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs