Assessment Year | 2005 |
---|---|
Principal Product | Processed Meat |
NAICS | 311613: Rendering and Meat Byproduct Processing |
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
56,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $128,716 | 3,444,480 |
kWh
|
$0.037 |
Electricity Demand | $66,705 | 6,754 |
kW-mo/yr
|
$9.88 |
Electricity Fees | $2,931 | - |
|
- |
Natural Gas | $125,382 | 16,569 |
MMBtu
|
$7.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,690 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2447: Heat water with exhaust heat | $35,536 | $19,550 | - | - | - |
$35,536
-
MMBtu
|
|
02 | 2.7124: Make a practice of turning off lights when not needed | $8,485 | $5,832 |
$8,360
238,919
kWh
|
- | $125 | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $6,356 | $15,064 | - | - | - |
$6,356
-
MMBtu
|
|
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,508 | $2,000 | - | - | - |
$5,508
-
MMBtu
|
|
05 | 2.2135: Repair and eliminate steam leaks | $5,356 | $94 | - | - | - |
$5,356
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,129 | $7,926 |
$2,854
81,556
kWh
|
$1,214
-
kW-mo/yr
|
$61 | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,110 | $2,387 |
$2,154
61,550
kWh
|
$911
-
kW-mo/yr
|
$45 | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,342 | $7,035 |
$1,592
45,489
kWh
|
$715
-
kW-mo/yr
|
$35 | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,636 | $5,788 |
$2,597
74,231
kWh
|
- | $39 | - | |
10 | 2.7124: Make a practice of turning off lights when not needed | $1,135 | - |
$1,118
31,959
kWh
|
- | $17 | - | |
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $672 | $223 |
$661
18,901
kWh
|
- | $11 | - | |
12 | 2.7229: Air condition only space necessary | $425 | $120 |
$137
3,923
kWh
|
$282
-
kW-mo/yr
|
$6 | - | |
TOTAL RECOMMENDED | $75,690 | $66,019 |
$19,473
556,528
kWh
|
$3,122
-
kW-mo/yr
|
$339 |
$52,756
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs