ITAC Assessment: MS0262
ITAC logo
ITAC Assessment: MS0262
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Lumber
NAICS 321113: Sawmills
SIC 2421: Sawmills and Planing Mills, General
Sales Range $50
M
to 100
M
# of Employees 200
Plant Area 250,000
ft2
Annual Production 235,000,000
thousand feet
Production Hrs. Annual 5,000
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,056,226 30,615,254
kWh
Electricity Demand $379,562 65,157
kW-mo/yr
Electricity Fees $444,194 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $115,085 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $44,456

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $56,439 $32,850 $27,771
804,960
kWh
$6,197
-
kW-mo/yr
$22,471
02 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $15,412 $1,518 $6,347
183,961
kWh
$3,396
-
kW-mo/yr
$5,669
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $14,422 $20,370 $6,412
185,861
kWh
$2,526
-
kW-mo/yr
$5,484
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $12,889 $406 $7,369
213,587
kWh
- $5,520
05 2.7124: Make a practice of turning off lights when not needed $9,490 $6,318 $5,426
157,271
kWh
- $4,064
06 2.4239: Eliminate or reduce compressed air usage $3,878 $3,710 $2,217
64,262
kWh
- $1,661
07 2.7221: Lower temperature during the winter season and vice-versa $918 $2,125 $525
15,215
kWh
- $393
08 2.7142: Utilize higher efficiency lamps and/or ballasts $822 $1,969 $405
11,730
kWh
$90
-
kW-mo/yr
$327
09 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $815 $444 $466
13,509
kWh
- $349
TOTAL RECOMMENDED $115,085 $69,710 $56,938
1,650,356
kWh
$12,209
-
kW-mo/yr
$45,938
TOTAL IMPLEMENTED $44,456 $24,863 $21,119
612,133
kWh
$5,922
-
kW-mo/yr
$17,415
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings