Assessment Year | 2004 |
---|---|
Principal Product | Cardboard Boxes |
NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
250,000
ft2
|
Annual Production | 700,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,849 | 5,500,500 |
kWh
|
$0.045 |
Electricity Demand | $41,389 | 12,773 |
kW-mo/yr
|
$3.24 |
Electricity Fees | $95,035 | - |
|
- |
Natural Gas | $319,960 | 45,973 |
MMBtu
|
$6.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,706 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,624 | $25,372 |
$12,698
308,268
kWh
|
$1,895
-
kW-mo/yr
|
$9,031 | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $15,290 | $15,000 | - | - | - |
$15,290
-
MMBtu
|
|
03 | 2.7231: Use radiant heater for spot heating | $6,881 | $3,275 | - | - | - |
$6,881
-
MMBtu
|
|
04 | 2.4239: Eliminate or reduce compressed air usage | $4,978 | $2,968 |
$2,966
72,002
kWh
|
- | $2,012 | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,530 | $1,992 |
$1,894
45,992
kWh
|
$288
-
kW-mo/yr
|
$1,348 | - | |
06 | 2.6218: Turn off equipment when not in use | $1,883 | - |
$1,122
27,232
kWh
|
- | $761 | - | |
07 | 2.2135: Repair and eliminate steam leaks | $1,491 | $19 | - | - | - |
$1,491
-
MMBtu
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,148 | $3,031 |
$617
14,976
kWh
|
$93
-
kW-mo/yr
|
$438 | - | |
09 | 2.7132: Install timers on light switches in little used areas | $881 | $66 |
$432
10,483
kWh
|
$128
-
kW-mo/yr
|
$321 | - | |
TOTAL RECOMMENDED | $59,706 | $51,723 |
$19,729
478,953
kWh
|
$2,404
-
kW-mo/yr
|
$13,911 |
$23,662
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs