Assessment Year | 2004 |
---|---|
Principal Product | Coaxial Cable |
NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $10 M to 50M |
# of Employees | 77 |
Plant Area |
178,000
ft2
|
Annual Production | 154,900,000
thousand feet
|
Production Hrs. Annual | 5,400
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $232,083 | 5,391,412 |
kWh
|
$0.043 |
Electricity Demand | $54,248 | 13,699 |
kW-mo/yr
|
$3.96 |
Electricity Fees | $67,875 | - |
|
- |
Natural Gas | $14,386 | 1,364 |
MMBtu
|
$10.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,051 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $6,530 | $120 | n/a |
$4,323
98,890
kWh
|
$690
-
kW-mo/yr
|
$1,517 | - | - |
02 | 2.7229: Air condition only space necessary | $4,615 | $2,282 | n/a |
$3,503
80,138
kWh
|
- | $1,112 | - | - |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,390 | $9,688 | n/a |
$2,798
64,012
kWh
|
$581
-
kW-mo/yr
|
$1,011 | - | - |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,247 | $4,074 | n/a |
$2,120
48,499
kWh
|
$375
-
kW-mo/yr
|
$752 | - | - |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,960 | $8,090 | n/a |
$1,961
44,851
kWh
|
$312
-
kW-mo/yr
|
$687 | - | - |
06 | 3.6124: Burn waste oil for heat | $2,232 | $2,190 | n/a | - | - | - |
$2,232
-
MMBtu
|
- |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,777 | $228 | n/a |
$1,348
23,733
kWh
|
- | $429 | - | - |
08 | 4.812: Apply for investment incentives | $740 | $25 | n/a | - | - | - | - | $740 |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $560 | $1,033 | n/a |
$425
9,731
kWh
|
- | $135 | - | - |
TOTAL RECOMMENDED | $27,051 | $27,730 |
$16,478
369,854
kWh
|
$1,958
-
kW-mo/yr
|
$5,643 |
$2,232
-
MMBtu
|
$740 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs