Assessment Year 2012
Principal Product Kitchen and bathroom cabinets
NAICS 337110: Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2434: Wood Kitchen Cabinets
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 200,000
ft2
Annual Production 60,000
pieces
Production Hrs. Annual 1,992
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $168,789 2,432,130
kWh
Electricity Demand $94,885 12,010
kW-mo/yr
Electricity Fees $35,915 -
Natural Gas $1,736 225
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $181,270 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $180,440

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.3212: Optimize plant power factor $42,700 $60,200 - $42,700
-
kW-mo/yr
- - -
02 2.8121: Apply for tax-free status for energy purchases $109,000 $10,900 - - $21,800 - $87,200
03 2.8123: Pay utility bills on time $9,700 - - - $9,700 - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $4,300 $17,365 $2,560
36,600
kWh
$1,740
-
kW-mo/yr
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,510 $620 $1,480
21,220
kWh
$1,030
-
kW-mo/yr
- - -
06 2.8121: Apply for tax-free status for energy purchases $12,130 $1,200 - - $2,430 - $9,700
07 2.7142: Utilize higher efficiency lamps and/or ballasts $830 $500 $190
2,660
kWh
$30
-
kW-mo/yr
- $610 -
08 2.7121: Utilize daylight whenever possible in lieu of artificial light $100 - $60
890
kWh
$40
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $181,270 $90,785 $4,290
61,370
kWh
$45,540
-
kW-mo/yr
$33,930 $610 $96,900
TOTAL IMPLEMENTED $180,440 $90,285 $4,100
58,710
kWh
$45,510
-
kW-mo/yr
$33,930 - $96,900
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs