Assessment Year | 2003 |
---|---|
Principal Product | Investment castings |
NAICS | 331512: Steel Investment Foundries |
SIC | 3324: Steel Investment Foundries |
Sales Range | $1 M to 5M |
# of Employees | 23 |
Plant Area |
30,000
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $67,998 | 1,868,080 |
kWh
|
$0.036 |
Electricity Demand | $109,611 | 9,842 |
kW-mo/yr
|
$11.14 |
Electricity Fees | $11,132 | - |
|
- |
Natural Gas | $58,437 | 11,125 |
MMBtu
|
$5.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,712 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,165 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $48,240 | $31,484 | - |
$45,084
-
kW-mo/yr
|
$3,156 | - | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $7,927 | $50 | - | - | $7,927 | - | - | |
03 | 3.5221: Recycle casting sand | $6,972 | - | - | - | - | - |
$6,972
-
lb
|
|
04 | 2.7134: Use photocell controls | $864 | $334 |
$807
22,180
kWh
|
- | $57 | - | - | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $724 | $1,800 | - | - | - |
$724
-
MMBtu
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $514 | $1,080 |
$168
4,630
kWh
|
$312
-
kW-mo/yr
|
$34 | - | - | |
07 | 2.2135: Repair and eliminate steam leaks | $238 | $62 | - | - | - |
$238
-
MMBtu
|
- | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $233 | $602 | - | - | - |
$233
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $65,712 | $35,412 |
$975
26,810
kWh
|
$45,396
-
kW-mo/yr
|
$11,174 |
$1,195
-
MMBtu
|
$6,972
-
lb
|
||
TOTAL IMPLEMENTED | $8,165 | $112 | - | - | $7,927 |
$238
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs