ITAC Assessment: DS0061
ITAC logo
ITAC Assessment: DS0061
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Doors & Cabinets
NAICS
n/a
SIC 2421: Sawmills and Planing Mills, General
Sales Range $10
M
to 50
M
# of Employees 37
Plant Area 63,000
ft2
Annual Production 8,300
pieces
Production Hrs. Annual 2,795
hrs
Location (State) Minnesota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $28,327 912,075
kWh
Electricity Demand $25,666 3,408
kW-mo/yr
Electricity Fees $8,653 -
Natural Gas $26,958 5,431
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,626 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $22,626

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
01 2.4133: Use most efficient type of electric motors $993 $2,300 $319
10,258
kWh
$674
-
kW-mo/yr
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $854 $200 $565
18,171
kWh
$289
-
kW-mo/yr
- - -
03 2.3212: Optimize plant power factor $2,466 $1,050 - - - - $2,466
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,120 $11,350 $2,674
85,873
kWh
$1,446
-
kW-mo/yr
- - -
05 3.5315: Lease / purchase baler; sell cardboard to recycler $4,951 $4,500 - - - $4,951
-
lb
-
06 2.7224: Reduce space conditioning during non-working hours $9,242 $2,400 - - $9,242
-
MMBtu
- -
TOTAL RECOMMENDED $22,626 $21,800 $3,558
114,302
kWh
$2,409
-
kW-mo/yr
$9,242
-
MMBtu
$4,951
-
lb
$2,466
TOTAL IMPLEMENTED $22,626 $21,800 $3,558
114,302
kWh
$2,409
-
kW-mo/yr
$9,242
-
MMBtu
$4,951
-
lb
$2,466
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs