| Assessment Year | 2002 |
|---|---|
| Principal Product | Upholstered motion furniture |
| NAICS |
n/a
|
| SIC | 2512: Wood Household Furniture, Upholstered |
| Sales Range | $100 M to 500M |
| # of Employees | 465 |
| Plant Area |
500,000
ft2
|
| Annual Production | 345,000
pieces
|
| Production Hrs. Annual | 5,760
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $128,789 | 3,234,174 |
kWh
|
$0.040 |
| Electricity Demand | $113,525 | 12,935 |
kW-mo/yr
|
$8.78 |
| Electricity Fees | $8,463 | - |
|
- |
| Natural Gas | $34,584 | 3,340 |
MMBtu
|
$10.35 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $52,533 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $39,949 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $7,097 | $6,416 | - | - | - |
$7,097
-
MMBtu
|
|
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $30,947 | $16,790 | - | - | - |
$30,947
-
MMBtu
|
|
| 03 | 2.2437: Recover waste heat from equipment | $5,201 | $427 | - | - | - |
$5,201
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,736 | $1,189 |
$4,666
131,594
kWh
|
- | $70 | - | |
| 05 | 2.3212: Optimize plant power factor | $4,266 | $3,600 | - | - | $4,266 | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $286 | $375 |
$177
4,982
kWh
|
$105
-
kW-mo/yr
|
$4 | - | |
| TOTAL RECOMMENDED | $52,533 | $28,797 |
$4,843
136,576
kWh
|
$105
-
kW-mo/yr
|
$4,340 |
$43,245
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $39,949 | $21,579 |
$4,666
131,594
kWh
|
- | $4,336 |
$30,947
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs