Assessment Year | 2001 |
---|---|
Principal Product | Molded Plastic |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $500 k to 1M |
# of Employees | 15 |
Plant Area |
43,600
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $32,497 | 782,400 |
kWh
|
$0.042 |
Electricity Demand | $27,061 | 3,406 |
kW-mo/yr
|
$7.95 |
Electricity Fees | $(-11,938.0) | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,496 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,400 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $13,400 | $50 | - | - | $3,350 | $10,050 | |
02 | 2.7134: Use photocell controls | $433 | $186 |
$405
12,045
kWh
|
- | $28 | - | |
03 | 2.7122: Disconnect ballasts | $272 | $426 |
$82
2,437
kWh
|
$173
-
kW-mo/yr
|
$17 | - | |
04 | 2.2511: Insulate bare equipment | $55 | $147 |
$51
1,517
kWh
|
- | $4 | - | |
05 | 2.3212: Optimize plant power factor | $1,336 | $2,385 | - | - | $1,336 | - | |
TOTAL RECOMMENDED | $15,496 | $3,194 |
$538
15,999
kWh
|
$173
-
kW-mo/yr
|
$4,735 | $10,050 | ||
TOTAL IMPLEMENTED | $13,400 | $50 | - | - | $3,350 | $10,050 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs