| Assessment Year | 2000 |
|---|---|
| Principal Product | Wooden Furniture Frames |
| NAICS |
n/a
|
| SIC | 2812: Alkalies and Chlorine |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
100,000
ft2
|
| Annual Production | 180,000
pieces
|
| Production Hrs. Annual | 1,920
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $33,630 | 784,584 |
kWh
|
$0.043 |
| Electricity Demand | $40,646 | 5,275 |
kW-mo/yr
|
$7.71 |
| Electricity Fees | $8,512 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,208 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,875 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $7,083 | - | - | - | $7,083 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $532 | $193 |
$524
14,947
kWh
|
- | $8 | |
| 03 | 2.7226: Use computer programs to optimize hvac performance | $333 | $355 |
$328
9,379
kWh
|
- | $5 | |
| 04 | 2.7124: Make a practice of turning off lights when not needed | $260 | $141 |
$73
2,052
kWh
|
$183
-
kW-mo/yr
|
$4 | |
| TOTAL RECOMMENDED | $8,208 | $689 |
$925
26,378
kWh
|
$183
-
kW-mo/yr
|
$7,100 | ||
| TOTAL IMPLEMENTED | $7,875 | $334 |
$597
16,999
kWh
|
$183
-
kW-mo/yr
|
$7,095 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs