Assessment Year | 1999 |
---|---|
Principal Product | Injection Molded Plastic Parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
30,000
ft2
|
Annual Production | 18,000,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $457,607 | 8,864,889 |
kWh
|
$0.052 |
Electricity Demand | $58,179 | 22,223 |
kW-mo/yr
|
$2.62 |
Electricity Fees | $(-79,673.0) | - |
|
- |
Natural Gas | $1,349 | 268 |
MMBtu
|
$5.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $79,782 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $1,213 | $777 |
$1,508
29,601
kWh
|
- | $(-295.0) | - | |
02 | 2.3132: Recharge batteries on during off-peak demand periods | $1,311 | - | - |
$1,292
-
kW-mo/yr
|
$19 | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $67,127 | $252,750 |
$76,769
1,508,206
kWh
|
$5,316
-
kW-mo/yr
|
$(-14,958.0) | - | |
04 | 2.2511: Insulate bare equipment | $1,671 | $682 |
$2,078
40,739
kWh
|
- | $(-407.0) | - | |
05 | 2.3212: Optimize plant power factor | $6,859 | $12,500 | - | - | $6,859 | - | |
06 | 3.7196: Use re-usable filters | $1,601 | $697 | - | - | - | $1,601 | |
TOTAL RECOMMENDED | $79,782 | $267,406 |
$80,355
1,578,546
kWh
|
$6,608
-
kW-mo/yr
|
$(-8,782.0) | $1,601 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs