Assessment Year | 1997 |
---|---|
Principal Product | marine animal oil products |
NAICS |
n/a
|
SIC | 2077: Animal and Marine Fats and Oils |
Sales Range | $5 M to 10M |
# of Employees | 25 |
Plant Area |
20,000
ft2
|
Annual Production | 46,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $237,890 | 4,900,645 |
kWh
|
$0.049 |
Electricity Demand | $49,259 | 12,405 |
kW-mo/yr
|
$3.97 |
Electricity Fees | $6,358 | - |
|
- |
Natural Gas | $698,043 | 197,499 |
MMBtu
|
$3.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $226,004 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $6,352 | $9,450 | n/a | - |
$4,589
-
kW-mo/yr
|
$1,763 | - | - | - | - |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $22,136 | $49,751 | n/a |
$19,010
422,333
kWh
|
$3,126
-
kW-mo/yr
|
- | - | - | - | - |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $39,339 | $58,400 | n/a | - | - | - |
$39,339
-
MMBtu
|
- | - | - |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $17,921 | $1,000 | n/a | - | - | - |
$17,921
-
MMBtu
|
- | - | - |
05 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $480 | - | n/a | - | - | - | - |
$240
-
lb
|
$(-240.0) | $480 |
06 | 4.452: Eliminate shift | $139,776 | - | n/a | - | - | - | - | - | $139,776 | - |
TOTAL RECOMMENDED | $226,004 | $118,601 |
$19,010
422,333
kWh
|
$7,715
-
kW-mo/yr
|
$1,763 |
$57,260
-
MMBtu
|
$240
-
lb
|
$139,536 | $480 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs