Assessment Year | 1997 |
---|---|
Principal Product | steel castings |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 99 |
Plant Area |
61,000
ft2
|
Annual Production | 2,700
ton
|
Production Hrs. Annual | 5,880
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $210,459 | 5,450,469 |
kWh
|
$0.039 |
Electricity Demand | $87,718 | 19,936 |
kW-mo/yr
|
$4.40 |
Electricity Fees | $(-4,598.0) | - |
|
- |
Natural Gas | $102,768 | 27,985 |
MMBtu
|
$3.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $125,619 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,250 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $356 | $1,798 |
$218
6,741
kWh
|
$174
-
kW-mo/yr
|
$(-36.0) | - | - | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,263 | $7,718 |
$1,512
46,307
kWh
|
- | $(-249.0) | - | - | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $43,945 | $22,016 | - | - | - |
$43,945
-
MMBtu
|
- | - | |
04 | 3.5222: Use sand for other purposes (eg construction fill, cover for municipal landfills) | $46,250 | - | - | - | - | - |
$46,250
-
lb
|
- | |
05 | 3.5113: Sell oil to recycler | $205 | - | - | - | - | - | - | $205 | |
06 | 4.522: Modify storage space to avoid rental of a warehouse | $33,600 | $153,600 | - | - | - | - | - | $33,600 | |
TOTAL RECOMMENDED | $125,619 | $185,132 |
$1,730
53,048
kWh
|
$174
-
kW-mo/yr
|
$(-285.0) |
$43,945
-
MMBtu
|
$46,250
-
lb
|
$33,805 | ||
TOTAL IMPLEMENTED | $46,250 | - | - | - | - | - |
$46,250
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs