Assessment Year | 1997 |
---|---|
Principal Product | Industrial and Commercial Machinery |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 63 |
Plant Area |
80,000
ft2
|
Annual Production | 4,500,000
lb
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $36,593 | 702,814 |
kWh
|
$0.052 |
Electricity Demand | $11,384 | 3,818 |
kW-mo/yr
|
$2.98 |
Electricity Fees | $15,021 | - |
|
- |
LPG | $20,560 | 2,249 |
MMBtu
|
$9.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $116,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $98,899 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $2,171 | $698 |
$1,818
38,101
kWh
|
- | $353 | - | - | |
02 | 2.6218: Turn off equipment when not in use | $15,115 | - |
$8,495
177,902
kWh
|
$3,407
-
kW-mo/yr
|
$3,213 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,984 | $53 |
$3,336
69,754
kWh
|
- | $648 | - | - | |
04 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $79,800 | $6,490 | - | - | - | $79,800 | - | |
05 | 4.514: Re-arrange equipment layout to reduce handling costs | $15,120 | $2,303 | - | - | - | - | $15,120 | |
TOTAL RECOMMENDED | $116,190 | $9,544 |
$13,649
285,757
kWh
|
$3,407
-
kW-mo/yr
|
$4,214 | $79,800 | $15,120 | ||
TOTAL IMPLEMENTED | $98,899 | $6,543 |
$11,831
247,656
kWh
|
$3,407
-
kW-mo/yr
|
$3,861 | $79,800 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs