| Assessment Year | 1996 |
|---|---|
| Principal Product | Steel Containers |
| NAICS |
n/a
|
| SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
| Sales Range | $5 M to 10M |
| # of Employees | 75 |
| Plant Area |
150,000
ft2
|
| Annual Production | 944,000
pieces
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $134,960 | 2,555,686 |
kWh
|
$0.053 |
| Electricity Demand | $23,990 | 8,939 |
kW-mo/yr
|
$2.68 |
| Electricity Fees | $3,994 | - |
|
- |
| Natural Gas | $117,641 | 31,460 |
MMBtu
|
$3.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $70,243 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,812 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,503 | $11,651 |
$2,925
55,979
kWh
|
$578
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4314: Use synthetic lubricant | $2,812 | $610 |
$2,351
44,842
kWh
|
$461
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $44,129 | $12,825 | - | - |
$44,129
-
MMBtu
|
- | - | |
| 04 | 3.8142: Distill contaminated solvents for reuse | $19,799 | $15,000 |
$(-782.0)
(-12,603)
kWh
|
- | - |
$21,601
-
gal
|
$(-1,020.0) | |
| TOTAL RECOMMENDED | $70,243 | $40,086 |
$4,494
88,218
kWh
|
$1,039
-
kW-mo/yr
|
$44,129
-
MMBtu
|
$21,601
-
gal
|
$(-1,020.0) | ||
| TOTAL IMPLEMENTED | $2,812 | $610 |
$2,351
44,842
kWh
|
$461
-
kW-mo/yr
|
- | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs