Assessment Year | 1996 |
---|---|
Principal Product | Electric Tools |
NAICS |
n/a
|
SIC | 2328: |
Sales Range | $50 M to 100M |
# of Employees | 126 |
Plant Area |
74,548
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,215 | 1,643,904 |
kWh
|
$0.053 |
Electricity Demand | $13,425 | 4,456 |
kW-mo/yr
|
$3.01 |
Electricity Fees | $24,380 | - |
|
- |
Natural Gas | $2,605 | 540 |
MMBtu
|
$4.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,311 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,273 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $1,416 | $1,049 | - | - | - |
$1,416
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,005 | $18,850 |
$6,374
133,646
kWh
|
$1,043
-
kW-mo/yr
|
$1,588 | - | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $2,427 | - |
$1,897
43,083
kWh
|
$26
-
kW-mo/yr
|
$504 | - | - | |
04 | 2.7229: Air condition only space necessary | $4,606 | $282 |
$3,930
82,356
kWh
|
- | $676 | - | - | |
05 | 3.3131: Use evaporation to concentrate material | $3,857 | $10,000 | - | - | - | - |
$3,857
-
gal
|
|
TOTAL RECOMMENDED | $21,311 | $30,181 |
$12,201
259,085
kWh
|
$1,069
-
kW-mo/yr
|
$2,768 |
$1,416
-
MMBtu
|
$3,857
-
gal
|
||
TOTAL IMPLEMENTED | $5,273 | $11,049 | - | - | - |
$1,416
-
MMBtu
|
$3,857
-
gal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs