Assessment Year | 1996 |
---|---|
Principal Product | Roof Vents |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 131 |
Plant Area |
194,000
ft2
|
Annual Production | 10,350,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $219,387 | 3,649,766 |
kWh
|
$0.060 |
Electricity Fees | $(-23,955.0) | - |
|
- |
Natural Gas | $26,835 | 5,749 |
MMBtu
|
$4.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $903 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $3,394 | $2,089 |
$4,032
133,060
kWh
|
$(-638.0) | - | - | |
02 | 2.1116: Improve combustion control capability | $353 | $1,000 | - | - |
$353
-
MMBtu
|
- | |
03 | 2.7442: Keep doors and windows shut when not on use | $550 | $403 |
$653
21,688
kWh
|
$(-103.0) | - | - | |
04 | 2.2437: Recover waste heat from equipment | $2,942 | $4,417 | - | - |
$2,942
-
MMBtu
|
- | |
05 | 3.7196: Use re-usable filters | $198 | $330 | - | - | - | $198 | |
TOTAL RECOMMENDED | $7,437 | $8,239 |
$4,685
154,748
kWh
|
$(-741.0) |
$3,295
-
MMBtu
|
$198 | ||
TOTAL IMPLEMENTED | $903 | $1,403 |
$653
21,688
kWh
|
$(-103.0) |
$353
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs