| Assessment Year | 1996 |
|---|---|
| Principal Product | Roof Vents |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $50 M to 100M |
| # of Employees | 131 |
| Plant Area |
194,000
ft2
|
| Annual Production | 10,350,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $219,387 | 3,649,766 |
kWh
|
$0.060 |
| Electricity Fees | $(-23,955.0) | - |
|
- |
| Natural Gas | $26,835 | 5,749 |
MMBtu
|
$4.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $903 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $3,394 | $2,089 |
$4,032
133,060
kWh
|
$(-638.0) | - | - | |
| 02 | 2.1116: Improve combustion control capability | $353 | $1,000 | - | - |
$353
-
MMBtu
|
- | |
| 03 | 2.7442: Keep doors and windows shut when not on use | $550 | $403 |
$653
21,688
kWh
|
$(-103.0) | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $2,942 | $4,417 | - | - |
$2,942
-
MMBtu
|
- | |
| 05 | 3.7196: Use re-usable filters | $198 | $330 | - | - | - | $198 | |
| TOTAL RECOMMENDED | $7,437 | $8,239 |
$4,685
154,748
kWh
|
$(-741.0) |
$3,295
-
MMBtu
|
$198 | ||
| TOTAL IMPLEMENTED | $903 | $1,403 |
$653
21,688
kWh
|
$(-103.0) |
$353
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs