Assessment Year | 1996 |
---|---|
Principal Product | jackets |
NAICS |
n/a
|
SIC | 2329: Men's and Boys' Clothing, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 150 |
Plant Area |
120,000
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,645 | 640,387 |
kWh
|
$0.040 |
Electricity Demand | $28,567 | 3,390 |
kW-mo/yr
|
$8.43 |
Natural Gas | $16,120 | 3,675 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,999 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,969 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $2,295 | $3,000 |
$851
28,136
kWh
|
$1,444
-
kW-mo/yr
|
- | - | - | |
02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $9,787 | $24,862 |
$2,793
92,321
kWh
|
$6,994
-
kW-mo/yr
|
- | - | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $887 | $1,000 | - | - |
$887
-
MMBtu
|
- | - | |
04 | 3.7196: Use re-usable filters | $1,090 | $900 | - | - | - |
$2
-
lb
|
$1,088 | |
05 | 3.5313: Increase amount of waste recovered for resale | $2,940 | - | - | - | - |
$2,940
-
lb
|
- | |
TOTAL RECOMMENDED | $16,999 | $29,762 |
$3,644
120,457
kWh
|
$8,438
-
kW-mo/yr
|
$887
-
MMBtu
|
$2,942
-
lb
|
$1,088 | ||
TOTAL IMPLEMENTED | $12,969 | $28,862 |
$3,644
120,457
kWh
|
$8,438
-
kW-mo/yr
|
$887
-
MMBtu
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs