| Assessment Year | 1996 |
|---|---|
| Principal Product | jackets |
| NAICS |
n/a
|
| SIC | 2329: Men's and Boys' Clothing, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 150 |
| Plant Area |
120,000
ft2
|
| Annual Production | 200,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,645 | 640,387 |
kWh
|
$0.040 |
| Electricity Demand | $28,567 | 3,390 |
kW-mo/yr
|
$8.43 |
| Natural Gas | $16,120 | 3,675 |
MMBtu
|
$4.39 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,999 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,969 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $2,295 | $3,000 |
$851
28,136
kWh
|
$1,444
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $9,787 | $24,862 |
$2,793
92,321
kWh
|
$6,994
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $887 | $1,000 | - | - |
$887
-
MMBtu
|
- | - | |
| 04 | 3.7196: Use re-usable filters | $1,090 | $900 | - | - | - |
$2
-
lb
|
$1,088 | |
| 05 | 3.5313: Increase amount of waste recovered for resale | $2,940 | - | - | - | - |
$2,940
-
lb
|
- | |
| TOTAL RECOMMENDED | $16,999 | $29,762 |
$3,644
120,457
kWh
|
$8,438
-
kW-mo/yr
|
$887
-
MMBtu
|
$2,942
-
lb
|
$1,088 | ||
| TOTAL IMPLEMENTED | $12,969 | $28,862 |
$3,644
120,457
kWh
|
$8,438
-
kW-mo/yr
|
$887
-
MMBtu
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs