Assessment Year | 1995 |
---|---|
Principal Product | Plastic Products |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
176,000
ft2
|
Annual Production | 16,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $609,035 | 11,282,532 |
kWh
|
$0.054 |
Natural Gas | $11,505 | 1,755 |
MMBtu
|
$6.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $99,775 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $99,775 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $64,604 | $60,000 |
$64,604
-
kWh
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $12,635 | - |
$12,635
-
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $348 | $778 |
$348
5,862
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,264 | $4,785 | - |
$1,264
-
MMBtu
|
|
05 | 2.7124: Make a practice of turning off lights when not needed | $13,524 | $1,400 |
$13,524
444,314
kWh
|
- | |
06 | 2.7231: Use radiant heater for spot heating | $7,400 | $3,132 | - |
$7,400
-
MMBtu
|
|
TOTAL RECOMMENDED | $99,775 | $70,095 |
$91,111
450,176
kWh
|
$8,664
-
MMBtu
|
||
TOTAL IMPLEMENTED | $99,775 | $70,095 |
$91,111
450,176
kWh
|
$8,664
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs