| Assessment Year | 1995 |
|---|---|
| Principal Product | Plastic Products |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
176,000
ft2
|
| Annual Production | 16,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $609,035 | 11,282,532 |
kWh
|
$0.054 |
| Natural Gas | $11,505 | 1,755 |
MMBtu
|
$6.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $99,775 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $99,775 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $64,604 | $60,000 |
$64,604
-
kWh
|
- | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $12,635 | - |
$12,635
-
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $348 | $778 |
$348
5,862
kWh
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $1,264 | $4,785 | - |
$1,264
-
MMBtu
|
|
| 05 | 2.7124: Make a practice of turning off lights when not needed | $13,524 | $1,400 |
$13,524
444,314
kWh
|
- | |
| 06 | 2.7231: Use radiant heater for spot heating | $7,400 | $3,132 | - |
$7,400
-
MMBtu
|
|
| TOTAL RECOMMENDED | $99,775 | $70,095 |
$91,111
450,176
kWh
|
$8,664
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $99,775 | $70,095 |
$91,111
450,176
kWh
|
$8,664
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs