Assessment Year | 1995 |
---|---|
Principal Product | Pine Lumber |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 167 |
Plant Area |
25,000
ft2
|
Annual Production | 113,000
thousand feet
|
Production Hrs. Annual | 8,372
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $688,038 | 15,956,038 |
kWh
|
$0.043 |
Natural Gas | $12,046 | 2,795 |
MMBtu
|
$4.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,241 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,263 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $611 | $1,933 |
$611
28,429
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $5,874 | $11,070 |
$5,874
272,860
kWh
|
|
03 | 2.7134: Use photocell controls | $721 | $900 |
$721
33,411
kWh
|
|
04 | 2.4314: Use synthetic lubricant | $2,652 | $800 |
$2,652
123,095
kWh
|
|
05 | 2.3212: Optimize plant power factor | $11,383 | $30,979 |
$11,383
-
kWh
|
|
TOTAL RECOMMENDED | $21,241 | $45,682 |
$21,241
457,795
kWh
|
||
TOTAL IMPLEMENTED | $3,263 | $2,733 |
$3,263
151,524
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs