Assessment Year | 2025 |
---|---|
Principal Product | Rice Milling |
NAICS | 311212: Rice Milling |
SIC | 2044: Rice Milling |
Sales Range | $1 M to 5M |
# of Employees | 65 |
Plant Area |
33,768
ft2
|
Annual Production | 87,600
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,086 | 1,323,120 |
kWh
|
$0.052 |
Electricity Demand | $42,528 | 2,949 |
kW-mo/yr
|
$14.42 |
Electricity Fees | $6,546 | - |
|
- |
TOTAL YEARLY COSTS | $118,160 | |||
RECOMMENDED SAVINGS* | $23,009 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $393 | - |
$393
7,558
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,056 | - |
$1,056
20,276
kWh
|
- | |
03 | 2.4131: Size electric motors for peak operating efficiency | $18,894 | $485,500 |
$14,215
269,217
kWh
|
$4,679
-
kW-mo/yr
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,666 | $39,130 |
$1,894
36,289
kWh
|
$772
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $23,009 | $524,630 |
$17,558
333,340
kWh
|
$5,451
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs