| Assessment Year | 1995 |
|---|---|
| Principal Product | Staples,Nails,Full Cells |
| NAICS |
n/a
|
| SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
150,000
ft2
|
| Annual Production | 20,958,572
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $346,428 | 6,223,623 |
kWh
|
$0.056 |
| Natural Gas | $48,667 | 7,043 |
MMBtu
|
$6.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,324 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $22,852 | $26,750 |
$22,852
-
kWh
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $2,588 | $4,300 |
$2,588
28,429
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,130 | $1,936 |
$1,130
12,309
kWh
|
- | - | |
| 04 | 2.1331: Burn a less expensive grade of fuel | $17,678 | $75,000 | - |
$48,667
-
MMBtu
|
$(-30,989.0)
-
MMBtu
|
|
| 05 | 2.7245: Use direct air supply to exhaust hoods | $950 | $600 |
$950
11,137
kWh
|
- | - | |
| 06 | 2.7124: Make a practice of turning off lights when not needed | $4,126 | - |
$4,126
131,594
kWh
|
- | - | |
| TOTAL RECOMMENDED | $49,324 | $108,586 |
$31,646
183,469
kWh
|
$48,667
-
MMBtu
|
$(-30,989.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs