Assessment Year | 1995 |
---|---|
Principal Product | Staples,Nails,Full Cells |
NAICS |
n/a
|
SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
150,000
ft2
|
Annual Production | 20,958,572
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $346,428 | 6,223,623 |
kWh
|
$0.056 |
Natural Gas | $48,667 | 7,043 |
MMBtu
|
$6.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,324 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $22,852 | $26,750 |
$22,852
-
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $2,588 | $4,300 |
$2,588
28,429
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,130 | $1,936 |
$1,130
12,309
kWh
|
- | - | |
04 | 2.1331: Burn a less expensive grade of fuel | $17,678 | $75,000 | - |
$48,667
-
MMBtu
|
$(-30,989.0)
-
MMBtu
|
|
05 | 2.7245: Use direct air supply to exhaust hoods | $950 | $600 |
$950
11,137
kWh
|
- | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $4,126 | - |
$4,126
131,594
kWh
|
- | - | |
TOTAL RECOMMENDED | $49,324 | $108,586 |
$31,646
183,469
kWh
|
$48,667
-
MMBtu
|
$(-30,989.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs