| Assessment Year | 1995 |
|---|---|
| Principal Product | Bottled Water and Carbonated Beverages |
| NAICS |
n/a
|
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
18,000
ft2
|
| Annual Production | 48,000,000
pieces
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,567 | 1,369,871 |
kWh
|
$0.070 |
| Natural Gas | $19,698 | 4,362 |
MMBtu
|
$4.52 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,483 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,992 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $1,304 | $3,500 | - |
$1,304
-
MMBtu
|
|
| 02 | 2.3212: Optimize plant power factor | $2,506 | $4,500 |
$2,506
-
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $2,296 | $7,800 |
$2,296
32,532
kWh
|
- | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $954 | $2,500 | - |
$954
-
MMBtu
|
|
| 05 | 2.4221: Install compressor air intakes in coolest locations | $727 | $1,000 |
$727
7,913
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $503 | $254 |
$503
6,741
kWh
|
- | |
| 07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,193 | $1,000 | - |
$1,193
-
MMBtu
|
|
| TOTAL RECOMMENDED | $9,483 | $20,554 |
$6,032
47,186
kWh
|
$3,451
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,992 | $9,054 |
$2,799
39,273
kWh
|
$1,193
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs