Assessment Year | 1994 |
---|---|
Principal Product | Automotive Ball Joints and Rack and Pinion Rebuilds |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
n/a
|
Annual Production | 5,632,550
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $91,829 | 2,914,420 |
kWh
|
$0.032 |
Natural Gas | $58,326 | 6,735 |
MMBtu
|
$8.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,248 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3132: Recharge batteries on during off-peak demand periods | $4,248 | - |
$4,248
-
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $2,747 | $1,500 | - |
$2,747
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,919 | $4,270 |
$1,919
44,842
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $850 | $277 |
$850
15,826
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $205 | - |
$205
3,810
kWh
|
- | |
TOTAL RECOMMENDED | $9,969 | $6,047 |
$7,222
64,478
kWh
|
$2,747
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,248 | - |
$4,248
-
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs