Assessment Year | 1994 |
---|---|
Principal Product | Aluminum billets |
NAICS |
n/a
|
SIC | 3365: Aluminum Foundries |
Sales Range | $5 M to 10M |
# of Employees | 19 |
Plant Area |
n/a
|
Annual Production | 10,549,892
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,795 | 1,041,032 |
kWh
|
$0.063 |
Natural Gas | $158,489 | 46,629 |
MMBtu
|
$3.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,229 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4131: Size electric motors for peak operating efficiency | $22,872 | $50 |
$22,872
571,805
kWh
|
- | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $10,637 | $20,000 | - |
$10,637
-
MMBtu
|
|
03 | 2.6127: Maintain air filters by cleaning or replacement | $2,702 | $651 |
$2,702
67,702
kWh
|
- | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $4,560 | $12,000 | - |
$4,560
-
MMBtu
|
|
05 | 2.4133: Use most efficient type of electric motors | $1,458 | $2,600 |
$1,458
36,342
kWh
|
- | |
TOTAL RECOMMENDED | $42,229 | $35,301 |
$27,032
675,849
kWh
|
$15,197
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs