| Assessment Year | 2000 |
|---|---|
| Principal Product | Prepress Operations |
| NAICS |
n/a
|
| SIC | 2731: Books: Publishing, or Publishing and Printing |
| Sales Range | $50 M to 100M |
| # of Employees | 400 |
| Plant Area |
74,000
ft2
|
| Annual Production | 1,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,069 | 1,402,110 |
kWh
|
$0.047 |
| Electricity Demand | $6,408 | 344 |
kW-mo/yr
|
$18.63 |
| Electricity Fees | $11,559 | - |
|
- |
| Natural Gas | $14,305 | 2,494 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,302 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,962 | $3,520 |
$1,850
33,411
kWh
|
$112
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $443 | $495 |
$406
7,327
kWh
|
$37
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $21,600 | $52,500 |
$21,600
458,382
kWh
|
- | - | - | - | |
| 04 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,170 | - | - | - |
$1,170
-
lb
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,948 | $750 | - | - | - | $2,948 | - | |
| 06 | 4.514: Re-arrange equipment layout to reduce handling costs | $5,897 | $12,000 | - | - | - | - | $5,897 | |
| TOTAL RECOMMENDED | $34,020 | $69,265 |
$23,856
499,120
kWh
|
$149
-
kW-mo/yr
|
$1,170
-
lb
|
$2,948 | $5,897 | ||
| TOTAL IMPLEMENTED | $8,302 | $16,015 |
$2,256
40,738
kWh
|
$149
-
kW-mo/yr
|
- | - | $5,897 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs