Assessment Year | 2004 |
---|---|
Principal Product | barley malt |
NAICS | 311213: Malt Manufacturing |
SIC | 2083: Malt |
Sales Range | $10 M to 50M |
# of Employees | 35 |
Plant Area |
10,000
ft2
|
Annual Production | 85,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $524,590 | 17,899,733 |
kWh
|
$0.029 |
Electricity Demand | $88,923 | 33,556 |
kW-mo/yr
|
$2.65 |
Electricity Fees | $62,717 | - |
|
- |
Natural Gas | $1,741,312 | 250,527 |
MMBtu
|
$6.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $673,661 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,126 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $25,126 | - |
$25,126
848,696
kWh
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $12,160 | $200 |
$10,840
365,960
kWh
|
$1,320
-
kW-mo/yr
|
- | |
03 | 2.5122: Replace high resistance ducts, pipes, and fittings | $495 | $400 |
$495
24,750
kWh
|
- | - | |
04 | 2.9121: Install wind powered electric generator | - | - | - | - | - | |
05 | 2.9121: Install wind powered electric generator | - | $40,000 | - | - | - | |
06 | 3.4113: Treat and reuse rinse waters | $635,880 | $1,705,000 | - | - |
$635,880
-
Tgal
|
|
TOTAL RECOMMENDED | $673,661 | $1,745,600 |
$36,461
1,239,406
kWh
|
$1,320
-
kW-mo/yr
|
$635,880
-
Tgal
|
||
TOTAL IMPLEMENTED | $25,126 | - |
$25,126
848,696
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |