Assessment Year | 1998 |
---|---|
Principal Product | Portland Cement |
NAICS |
n/a
|
SIC | 3241: Cement, Hydraulic |
Sales Range | $50 M to 100M |
# of Employees | 134 |
Plant Area |
218,000
ft2
|
Annual Production | 1,300,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,366,715 | 176,051,585 |
kWh
|
$0.025 |
Electricity Demand | $1,906,197 | 29,306 |
kW-mo/yr
|
$65.04 |
Electricity Fees | $5,934 | - |
|
- |
Natural Gas | $628,261 | 218,435 |
MMBtu
|
$2.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,847,053 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,539 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.611: Begin a practice of predictive / preventative maintenance | $1,364 | $3,550 | - | - | - | - | $1,364 | |
02 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $2,950,000 | $19,000,000 | - | - | - | $2,950,000 | - | |
03 | 2.7132: Install timers on light switches in little used areas | $4,256 | $7,500 |
$4,256
183,177
kWh
|
- | - | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $7,919 | $17,073 |
$6,163
265,240
kWh
|
$1,756
-
kW-mo/yr
|
- | - | - | |
05 | 2.4314: Use synthetic lubricant | $7,514 | $2,827 |
$5,693
245,018
kWh
|
$1,821
-
kW-mo/yr
|
- | - | - | |
06 | 3.5216: Recycle nonferrous dust | $876,000 | $900,000 | - | - |
$876,000
-
lb
|
- | - | |
TOTAL RECOMMENDED | $3,847,053 | $19,930,950 |
$16,112
693,435
kWh
|
$3,577
-
kW-mo/yr
|
$876,000
-
lb
|
$2,950,000 | $1,364 | ||
TOTAL IMPLEMENTED | $13,539 | $28,123 |
$10,419
448,417
kWh
|
$1,756
-
kW-mo/yr
|
- | - | $1,364 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs