Assessment Year | 1993 |
---|---|
Principal Product | integrated circuit testing equipment |
NAICS |
n/a
|
SIC | 3825: Instruments for Measuring and Testing of Electricity and Electrical Signals |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 135
pieces
|
Production Hrs. Annual | 2,528
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $217,878 | 3,679,074 |
kWh
|
$0.059 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,440 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $21,340 | $21,050 |
$21,340
-
kWh
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,500 | - |
$1,500
55,393
kWh
|
|
03 | 2.6218: Turn off equipment when not in use | $980 | - |
$980
35,170
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $330 | $50 |
$330
12,309
kWh
|
|
05 | 2.7111: Reduce illumination to minimum necessary levels | $4,590 | $4,420 |
$4,590
43,669
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $680 | $580 |
$680
7,034
kWh
|
|
TOTAL RECOMMENDED | $29,420 | $26,100 |
$29,420
153,575
kWh
|
||
TOTAL IMPLEMENTED | $28,440 | $26,100 |
$28,440
118,405
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs