Assessment Year | 1997 |
---|---|
Principal Product | Corrugated Packaging |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
150,000
ft2
|
Annual Production | 550,000,000
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,622 | 2,363,423 |
kWh
|
$0.025 |
Electricity Demand | $37,317 | 550 |
kW-mo/yr
|
$67.85 |
Electricity Fees | $7,332 | - |
|
- |
Natural Gas | $126,664 | 29,428 |
MMBtu
|
$4.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,101 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.611: Begin a practice of predictive / preventative maintenance | $10,045 | $3,500 | - | - | - | $10,045 | |
02 | 4.514: Re-arrange equipment layout to reduce handling costs | $6,750 | $12,500 | - | - | - | $6,750 | |
03 | 4.432: Cross-train personnel to avoid lost time | $6,400 | $15,000 | - | - | - | $6,400 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $670 | $1,696 |
$371
13,189
kWh
|
$299
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $185 | $115 |
$97
3,517
kWh
|
$88
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $94 | $276 |
$74
2,638
kWh
|
$20
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,007 | $40 |
$634
22,860
kWh
|
$373
-
kW-mo/yr
|
- | - | |
08 | 2.4133: Use most efficient type of electric motors | $1,707 | $2,024 |
$1,076
38,687
kWh
|
$631
-
kW-mo/yr
|
- | - | |
09 | 4.522: Modify storage space to avoid rental of a warehouse | $38,290 | $50,000 | - | - |
$38,290
-
lb
|
- | |
10 | 3.5314: Use in-process recycling whenever possible | $480 | $800 | - | - |
$480
-
lb
|
- | |
TOTAL RECOMMENDED | $65,628 | $85,951 |
$2,252
80,891
kWh
|
$1,411
-
kW-mo/yr
|
$38,770
-
lb
|
$23,195 | ||
TOTAL IMPLEMENTED | $19,101 | $22,611 |
$1,618
58,031
kWh
|
$1,038
-
kW-mo/yr
|
- | $16,445 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs