Assessment Year | 1997 |
---|---|
Principal Product | Pillows and Cushions |
NAICS |
n/a
|
SIC | 2392: House furnishing, Except Curtains and Draperies |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
44,000
ft2
|
Annual Production | 1,800,000
pieces
|
Production Hrs. Annual | 3,380
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $21,542 | 652,989 |
kWh
|
$0.033 |
Electricity Demand | $18,062 | 300 |
kW-mo/yr
|
$60.21 |
Electricity Fees | $2,467 | - |
|
- |
Natural Gas | $17,269 | 2,051 |
MMBtu
|
$8.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,332 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,435 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.432: Cross-train personnel to avoid lost time | $4,640 | $12,500 | - | - | - | $4,640 | |
02 | 4.514: Re-arrange equipment layout to reduce handling costs | $3,960 | $10,000 | - | - | - | $3,960 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,211 | $4,172 |
$1,392
37,808
kWh
|
$819
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,394 | $3,145 |
$870
23,740
kWh
|
$524
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $86 | $207 |
$74
2,052
kWh
|
$12
-
kW-mo/yr
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,441 | $52 |
$827
22,567
kWh
|
$614
-
kW-mo/yr
|
- | - | |
07 | 3.7196: Use re-usable filters | $12,954 | $4,229 | - | - |
$12,954
-
lb
|
- | |
08 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,646 | $5,240 | - | - |
$3,646
-
lb
|
- | |
TOTAL RECOMMENDED | $30,332 | $39,545 |
$3,163
86,167
kWh
|
$1,969
-
kW-mo/yr
|
$16,600
-
lb
|
$8,600 | ||
TOTAL IMPLEMENTED | $11,435 | $25,697 |
$1,697
46,307
kWh
|
$1,138
-
kW-mo/yr
|
- | $8,600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs