Assessment Year | 1997 |
---|---|
Principal Product | Custom-Fabricated Stainless Steel Products |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
120,000
ft2
|
Annual Production | 638
pieces
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,189 | 2,257,327 |
kWh
|
$0.025 |
Electricity Demand | $38,627 | 6,547 |
kW-mo/yr
|
$5.90 |
Natural Gas | $12,234 | 2,835 |
MMBtu
|
$4.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,312 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,485 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.711: Initiate a total quality management program | $7,839 | $15,000 | - | - | - | - | $7,839 | |
02 | 4.514: Re-arrange equipment layout to reduce handling costs | $4,725 | $10,000 | - | - | - | - | $4,725 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,218 | $4,096 |
$1,440
51,876
kWh
|
$778
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,048 | $1,583 |
$683
24,326
kWh
|
$365
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $215 | - |
$146
4,982
kWh
|
$69
-
kW-mo/yr
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $2,497 | $197 |
$1,629
57,737
kWh
|
$868
-
kW-mo/yr
|
- | - | - | |
07 | 3.5314: Use in-process recycling whenever possible | $4,550 | - | - | - | - |
$4,550
-
lb
|
- | |
08 | 3.5143: Return spent solutions to the manufacturer | $220 | - | - | - |
$220
-
gal
|
- | - | |
TOTAL RECOMMENDED | $23,312 | $30,876 |
$3,898
138,921
kWh
|
$2,080
-
kW-mo/yr
|
$220
-
gal
|
$4,550
-
lb
|
$12,564 | ||
TOTAL IMPLEMENTED | $8,485 | $11,780 |
$2,458
87,045
kWh
|
$1,302
-
kW-mo/yr
|
- | - | $4,725 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs