ITAC Assessment: MO0196
ITAC logo
ITAC Assessment: MO0196
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product Custom-Fabricated Stainless Steel Products
NAICS
n/a
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 240
Plant Area 120,000
ft2
Annual Production 638
pieces
Production Hrs. Annual 4,800
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $56,189 2,257,327
kWh
Electricity Demand $38,627 6,547
kW-mo/yr
Natural Gas $12,234 2,835
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,312 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,485

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
01 4.711: Initiate a total quality management program $7,839 $15,000 - - - - $7,839
02 4.514: Re-arrange equipment layout to reduce handling costs $4,725 $10,000 - - - - $4,725
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,218 $4,096 $1,440
51,876
kWh
$778
-
kW-mo/yr
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,048 $1,583 $683
24,326
kWh
$365
-
kW-mo/yr
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $215 - $146
4,982
kWh
$69
-
kW-mo/yr
- - -
06 2.4221: Install compressor air intakes in coolest locations $2,497 $197 $1,629
57,737
kWh
$868
-
kW-mo/yr
- - -
07 3.5314: Use in-process recycling whenever possible $4,550 - - - - $4,550
-
lb
-
08 3.5143: Return spent solutions to the manufacturer $220 - - - $220
-
gal
- -
TOTAL RECOMMENDED $23,312 $30,876 $3,898
138,921
kWh
$2,080
-
kW-mo/yr
$220
-
gal
$4,550
-
lb
$12,564
TOTAL IMPLEMENTED $8,485 $11,780 $2,458
87,045
kWh
$1,302
-
kW-mo/yr
- - $4,725
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs