| Assessment Year | 1995 |
|---|---|
| Principal Product | Electric Motors |
| NAICS |
n/a
|
| SIC | 3621: Motors and Generators |
| Sales Range | $10 M to 50M |
| # of Employees | 350 |
| Plant Area |
145,000
ft2
|
| Annual Production | 150,000
units
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $680,352 | 12,644,490 |
kWh
|
$0.054 |
| LPG | $90,472 | 20,672 |
MMBtu
|
$4.38 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $81,041 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,472 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $27,601 | $17,901 |
$27,601
109,906
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,472 | $15,370 |
$4,472
83,822
kWh
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $530 | $25 |
$530
10,258
kWh
|
- | - | |
| 04 | 3.4114: Replace city water with recycled water via cooling tower | $9,918 | $2,845 |
$(-223.0)
(-4,982)
kWh
|
$10,141
-
Tgal
|
- | |
| 05 | 3.1163: Use plastic pallets instead of wood | $38,520 | $36,113 | - | - |
$38,520
-
lb
|
|
| TOTAL RECOMMENDED | $81,041 | $72,254 |
$32,380
199,004
kWh
|
$10,141
-
Tgal
|
$38,520
-
lb
|
||
| TOTAL IMPLEMENTED | $4,472 | $15,370 |
$4,472
83,822
kWh
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs