Assessment Year | 1994 |
---|---|
Principal Product | Dies |
NAICS |
n/a
|
SIC | 3555: Printing Trades Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 134 |
Plant Area |
76,050
ft2
|
Annual Production | 7,800
pieces
|
Production Hrs. Annual | 6,888
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,002 | 1,434,349 |
kWh
|
$0.067 |
Natural Gas | $10,043 | 2,130 |
MMBtu
|
$4.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,463 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,382 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,096 | $12,303 |
$5,096
76,202
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,286 | $615 |
$3,286
48,945
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $5,207 | $7,456 |
$5,207
77,667
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $623 | $155 |
$623
9,379
kWh
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $600 | $295 |
$600
9,086
kWh
|
- | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,600 | $4,200 |
$2,288
34,291
kWh
|
$(-688.0)
-
MMBtu
|
|
07 | 2.6121: Reduce hot water temperature to the minimum required | $51 | $75 | - |
$51
-
MMBtu
|
|
TOTAL RECOMMENDED | $16,463 | $25,099 |
$17,100
255,570
kWh
|
$(-637.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,382 | $12,918 |
$8,382
125,147
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs