| Assessment Year | 1991 |
|---|---|
| Principal Product | SHELF-LIFE DAIRY PRODUCT |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $10 M to 50M |
| # of Employees | 105 |
| Plant Area |
n/a
|
| Annual Production | 42,000,000
lb
|
| Production Hrs. Annual | 3,094
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $197,997 | 3,775,498 |
kWh
|
$0.052 |
| Fuel Oil #6 | $140,036 | 55,688 |
MMBtu
|
$2.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,811 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #6 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $13,257 | $1,195 | - |
$13,257
-
MMBtu
|
- | |
| 02 | 2.1213: Direct warmest air to combustion intake | $1,762 | $705 | - |
$1,762
-
MMBtu
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,773 | $2,146 |
$1,773
33,705
kWh
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,256 | $30 |
$1,256
24,033
kWh
|
- | - | |
| 05 | 2.4312: Improve lubrication practices | $974 | - |
$974
18,464
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,198 | - |
$3,778
72,098
kWh
|
- | $(-580.0) | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,276 | $4,368 |
$2,276
43,376
kWh
|
- | - | |
| 08 | 2.4133: Use most efficient type of electric motors | $1,282 | $1,788 |
$1,282
24,326
kWh
|
- | - | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,033 | - |
$3,033
57,737
kWh
|
- | - | |
| TOTAL RECOMMENDED | $28,811 | $10,232 |
$14,372
273,739
kWh
|
$15,019
-
MMBtu
|
$(-580.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #6 Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs