Assessment Year | 1991 |
---|---|
Principal Product | BLOWERS |
NAICS |
n/a
|
SIC | 3563: Air and Gas Compressors |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 4,400
pieces
|
Production Hrs. Annual | 3,920
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,231 | 2,360,199 |
kWh
|
$0.051 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,304 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,304 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 3.4115: Recover and reuse cooling water | $5,709 | $704 |
$207
4,103
kWh
|
$5,502 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,614 | $306 |
$3,614
71,512
kWh
|
- | |
03 | 2.7492: Use proper thickness of insulation on building envelope | $4,798 | $573 |
$4,798
94,959
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $267 | $987 |
$267
5,275
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $194 | $1,013 |
$194
3,810
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $340 | - |
$340
6,741
kWh
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $222 | $300 |
$222
4,396
kWh
|
- | |
08 | 2.4312: Improve lubrication practices | $160 | $112 |
$160
3,224
kWh
|
- | |
TOTAL RECOMMENDED | $15,304 | $3,995 |
$9,802
194,020
kWh
|
$5,502 | ||
TOTAL IMPLEMENTED | $15,304 | $3,995 |
$9,802
194,020
kWh
|
$5,502 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs