Assessment Year | 1991 |
---|---|
Principal Product | CIRCUIT BOARDS |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $10 M to 50M |
# of Employees | 239 |
Plant Area |
n/a
|
Annual Production | 312,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $268,236 | 6,246,776 |
kWh
|
$0.043 |
Natural Gas | $88,545 | 17,901 |
MMBtu
|
$4.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,982 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,982 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,155 | $7,104 |
$4,155
93,200
kWh
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,664 | $695 | - |
$3,664
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,614 | $820 |
$2,614
58,617
kWh
|
- | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $2,488 | $500 | - |
$2,488
-
MMBtu
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $663 | $250 |
$663
14,947
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $398 | - |
$398
8,792
kWh
|
- | |
TOTAL RECOMMENDED | $13,982 | $9,369 |
$7,830
175,556
kWh
|
$6,152
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,982 | $9,369 |
$7,830
175,556
kWh
|
$6,152
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs