| Assessment Year | 1990 |
|---|---|
| Principal Product | RADIATORS FOR TRUCKS |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 300,000
pieces
|
| Production Hrs. Annual | 6,840
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $288,500 | 5,686,694 |
kWh
|
$0.051 |
| Natural Gas | $64,002 | 25,027 |
MMBtu
|
$2.56 |
| LPG | $63,399 | 22,472 |
MMBtu
|
$2.82 |
| Fuel Oil #2 | $2,117 | 606 |
MMBtu
|
$3.49 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,642 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,428 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $14,971 | $900 | - |
$14,971
-
MMBtu
|
|
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $12,118 | $15,000 | - |
$12,118
-
MMBtu
|
|
| 03 | 2.2444: Use hot process fluids to preheat incoming process fluids | $4,096 | $8,000 | - |
$4,096
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $795 | $306 |
$795
15,826
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $662 | - |
$662
13,189
kWh
|
- | |
| TOTAL RECOMMENDED | $32,642 | $24,206 |
$1,457
29,015
kWh
|
$31,185
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $16,428 | $1,206 |
$1,457
29,015
kWh
|
$14,971
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs