ITAC Assessment: MI0479
ITAC logo
ITAC Assessment: MI0479
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Seeds (Soybean and Cotton
NAICS 115114: Postharvest Crop Activities (except Cotton Ginning)
SIC 3451: Screw Machine Products
Sales Range $5
M
to 10
M
# of Employees 208
Plant Area 468,844
ft2
Annual Production 39,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) Puerto Rico

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,443,073 5,415,301
kWh
Electricity Demand $179,771 14,044
kW-mo/yr
Electricity Fees $3,604 -
TOTAL YEARLY COSTS $1,626,448
RECOMMENDED SAVINGS* $694,263 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.9114: Use solar heat to make electricty $623,934 $2,300 - - $623,934
02 2.4239: Eliminate or reduce compressed air usage $2,569 $185 $2,354
8,851
kWh
$215
-
kW-mo/yr
-
03 2.7232: Replace existing hvac unit with high efficiency model $33,391 $16,984 $32,522
122,264
kWh
$869
-
kW-mo/yr
-
04 2.7135: Install occupancy sensors $2,629 $3,761 $2,629
9,883
kWh
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $6,360 $16,755 $5,337
20,065
kWh
$1,023
-
kW-mo/yr
-
06 2.3212: Optimize plant power factor $25,380 $72,124 - $25,380
-
kW-mo/yr
-
TOTAL RECOMMENDED $694,263 $112,109 $42,842
161,063
kWh
$27,487
-
kW-mo/yr
$623,934
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs