| Assessment Year | 2026 |
|---|---|
| Principal Product | Maritime Systems |
| NAICS | 334511: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufactur |
| SIC | 3812: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical Systems and Instruments |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
152,000
ft2
|
| Annual Production | 5,000
units
|
| Production Hrs. Annual | 3,276
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $82,112 | 1,315,260 |
kWh
|
$0.062 |
| Electricity Demand | $48,888 | 3,375 |
kW-mo/yr
|
$14.49 |
| Electricity Fees | $24,152 | - |
|
- |
| TOTAL YEARLY COSTS | $155,152 | |||
| RECOMMENDED SAVINGS* | $51,030 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,889 | - | - |
$4,889
-
kW-mo/yr
|
|
| 02 | 2.7221: Lower temperature during the winter season and vice-versa | $27,548 | $480 |
$14,845
239,434
kWh
|
$12,703
-
kW-mo/yr
|
|
| 03 | 2.6218: Turn off equipment when not in use | $14,074 | $2,600 |
$14,074
227,007
kWh
|
- | |
| 04 | 2.3191: Use demand controller or load shedder | $4,519 | $18,392 | - |
$4,519
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $51,030 | $21,472 |
$28,919
466,441
kWh
|
$22,111
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs