Assessment Year | 2025 |
---|---|
Principal Product | Beverage Distribution company |
NAICS | 424810: Beer and Ale Merchant Wholesalers |
SIC | 5181: Beer and Ale |
Sales Range | $100 M to 500M |
# of Employees | 730 |
Plant Area |
325,000
ft2
|
Annual Production | 28,800,000
units
|
Production Hrs. Annual | 5,720
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $142,938 | 2,718,240 |
kWh
|
$0.053 |
Electricity Demand | $91,001 | 5,941 |
kW-mo/yr
|
$15.32 |
Electricity Fees | $36,192 | - |
|
- |
TOTAL YEARLY COSTS | $270,131 | |||
RECOMMENDED SAVINGS* | $37,096 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.3132: Recharge batteries on during off-peak demand periods | $4,871 | - | - |
$4,871
-
kW-mo/yr
|
|
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,549 | - | - |
$4,549
-
kW-mo/yr
|
|
03 | 2.7224: Reduce space conditioning during non-working hours | $4,194 | - |
$4,194
79,134
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $10,085 | $1,600 |
$10,085
190,277
kWh
|
- | |
05 | 2.7496: Install partitions to reduce size of conditioned space | $13,397 | $26,570 |
$9,185
173,302
kWh
|
$4,212
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $37,096 | $28,170 |
$23,464
442,713
kWh
|
$13,632
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |