| Assessment Year | 1995 |
|---|---|
| Principal Product | Electrical Discharge Machining |
| NAICS |
n/a
|
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 60 |
| Plant Area |
25,000
ft2
|
| Annual Production | 250,000
pieces
|
| Production Hrs. Annual | 2,718
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,517 | 995,604 |
kWh
|
$0.082 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,909 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,451 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $2,813 | $5,126 |
$2,813
33,705
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $255 | - |
$255
2,931
kWh
|
|
| 03 | 2.4314: Use synthetic lubricant | $637 | $320 |
$637
4,396
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,267 | $1,552 |
$1,267
17,585
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,184 | $2,843 |
$2,184
29,894
kWh
|
|
| 06 | 2.7241: Install outside air damper / economizer on hvac unit | $2,565 | $7,700 |
$2,565
48,066
kWh
|
|
| 07 | 2.7232: Replace existing hvac unit with high efficiency model | $7,188 | $27,775 |
$7,188
104,045
kWh
|
|
| TOTAL RECOMMENDED | $16,909 | $45,316 |
$16,909
240,622
kWh
|
||
| TOTAL IMPLEMENTED | $3,451 | $4,395 |
$3,451
47,479
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs