Assessment Year 1995
Principal Product Electrical Discharge Machining
NAICS
n/a
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 60
Plant Area 25,000
ft2
Annual Production 250,000
pieces
Production Hrs. Annual 2,718
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $81,517 995,604
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $16,909 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,451

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4133: Use most efficient type of electric motors $2,813 $5,126 $2,813
33,705
kWh
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $255 - $255
2,931
kWh
03 2.4314: Use synthetic lubricant $637 $320 $637
4,396
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,267 $1,552 $1,267
17,585
kWh
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,184 $2,843 $2,184
29,894
kWh
06 2.7241: Install outside air damper / economizer on hvac unit $2,565 $7,700 $2,565
48,066
kWh
07 2.7232: Replace existing hvac unit with high efficiency model $7,188 $27,775 $7,188
104,045
kWh
TOTAL RECOMMENDED $16,909 $45,316 $16,909
240,622
kWh
TOTAL IMPLEMENTED $3,451 $4,395 $3,451
47,479
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs