Assessment Year | 2025 |
---|---|
Principal Product | Primary Metal Products |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | greater than $500 M |
# of Employees | 50 |
Plant Area |
31,960
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,150 | 2,707,960 |
kWh
|
$0.044 |
Electricity Demand | $26,894 | 5,394 |
kW-mo/yr
|
$4.99 |
Electricity Fees | $18,991 | - |
|
- |
TOTAL YEARLY COSTS | $165,035 | |||
RECOMMENDED SAVINGS* | $45,637 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $15,504 | $2,400 |
$15,504
352,367
kWh
|
- | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $4,582 | $1,260 |
$3,505
79,666
kWh
|
$1,077
-
kW-mo/yr
|
|
03 | 2.7496: Install partitions to reduce size of conditioned space | $5,309 | $1,594 |
$4,596
104,458
kWh
|
$713
-
kW-mo/yr
|
|
04 | 2.7425: Clean or color roof to reduce solar load | $4,679 | $18,537 |
$3,572
81,182
kWh
|
$1,107
-
kW-mo/yr
|
|
05 | 2.9114: Use solar heat to make electricty | $15,563 | $77,756 |
$8,204
186,448
kWh
|
$7,359
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $45,637 | $101,547 |
$35,381
804,121
kWh
|
$10,256
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs